Universal Pressure Transducer (Gage or Absolute)

   
Model: UPT
  • A universal pressure transducer that is configurable to your requirements.
  • Select the Accuracy that you need along with the Range, Temperature & Output, Electrical Connection and Pressure Connection for your requirements. 
  • Ranges are available from 0-25 psi up to 0-10.000 psi.
  • Calibration Units of PSI, Inches of Hg, Bar, mBar, kPa, Inches H2O in Gage or Absolute Types. 
 
     
 
   
 
     
 
Products Specifications
Pressure Ranges 0-25 psi up to 0-10.000 psi.
Accuracy +/- 0.5% FS or better (Specify)
Sensitivity /Output 3 mV/V (+/- 2%).
Resolution Infinite
Overload Pressure To 150% of Calibrated Range
   
Temperature, Operating           -100°F to 250°F
Temperature, Compensated 60°F to 160°F
Temperature Effect,  Zero 0.0075% FS/ °F
Temperature Effect,  Span 0.01% Reading/ °F
   
Strain Gages Type Bonded foil
Excitation(Calibrated) 10 VDC
Excitation(acceptable) 12 VDC or AC Maximum
Bridge Insulation Resistance 5000 Ohm
Bridge Resistance 350 Ohms
Shunt Calibrated Data Included
Wiring Code
with Millivolt output
Red/Black         +/- Excitation
White/Green     +/- Signal
Electrical Termination Integral 5 ft, Four Conductor Shielded Cable with Polyurethane Jacket
Optional:Welded-on PTIH-10-6P (6 Pins) Quick Disconnect Connector (Hermetic)
   
Media  
Burst Pressure 300 % of Calibrated Range up to 5000 psi Ranges
200 % of Calibrated Range Greater than 5000 psi
Pressure Port
/ Pressure Connections  (Specify)
1/4-18NPT Inside Thread, Standard range up to 1500 psi
1/4-18NPT Outside Thread, Standard above 1500 psi
7/16-20 UNF Male, MS33656-E4 (37Degree flare)
7/16-20 UNF Female, MS33649-04
G 1/2 Male (British Pipe Thread)
Autoclave F250C,9/16-18 Thread
Other (Specify)
Material 17-4 PH SS
Weight 10 ounces
   
Options Specify Additional Cable length
High Level Outputs available 0-5 VDV, 0-10 VDC, and 4-20 mA Two Wire;
all with zero and span adjustments.     
High Lever Output increases
length
1.2 inches.
   
  Gage Pressure Transducers with ranges higher than 200 psi are sealed.
  Shunt calibration data recorded on Calibration Data Sheet
Zero Setting at +/- 2% Range Nominal
 


 

 
                 
  Pressure Transducers   Load Cells   Load Cell Accessories   Services  
  High Precision   Compression Only   Base/Pull Plates   Strain Gauging  
  Miniature Flush Diaphragm   Tension Only   Load Buttons   Re-Calibration  
  Steam Sterilizers   Compression/ Tension   Tongue Shackle   Transducer/Repair  
  Flush Diaphragm   Miniature Load Cell   Yoke Shackle      
  Universal Pressure Transducer   Universal Load Cell          
  Universal Differential   Low Profile Load Cell          
      Thru Hole Design Load Cell          
      Internally Threaded Mini Donut          
             
 
                 
 